Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Transfus Med Hemother ; 46(6): 440-445, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31933574

RESUMO

BACKGROUND: The human platelet alloantigens (HPA) HPA-1a and HPA-5b are located on glycoproteins on the platelet surface and are the most relevant to cause neonatal alloimmune thrombocytopenia (NAIT). The antigens are defined by single nucleotide polymorphisms (SNPs) in the glycoprotein genes, and the antigen status can be determined by genotyping the SNPs. However, genotyping is time-consuming and costly depending on the method and sample throughput. Here, we tested the reliability of the evanescence wave based fluorescence (EVA) biosensor technology for the rapid phenotyping of the HPA-1a and HPA-5b antigens on blood donor samples in two laboratories. METHODS: HPA-1a and HPA-5b phenotyping was performed on EDTA blood samples from 336 blood donors (Lyon: 216 donors; Mannheim: 120 donors) using EVA typing assays and the biosensor system (Davos Diagnostics, Davos, Switzerland). For genotyping, validated PCR-SSP and TaqMan-PCR methods were used. RESULTS: HPA-1a phenotyping was positive for all samples with HPA-1aa (n = 244; EVA value 807 ± 167 U/s) and HPA-1ab (n = 82; 542 ± 110 U/s) genotypes. All samples (n = 10) with negative EVA values (<10 U/s) had the HPA-1bb genotype. HPA-5b phenotyping was negative for all HPA-5aa genotypes (n = 267) and positive for the HPA-5ab (n = 66; 83 ± 22 U/s) and HPA-5bb (n = 3; 118 ± 25 U/s) genotypes. EVA values from heterozygotes were significantly lower compared to HPA-1a or HPA-5b homozygotes. A strong correlation of the EVA values with the platelet count in the blood samples was observed. CONCLUSION: EVA is a reliable method for rapid phenotyping of the clinically relevant HPA-1a and HPA-5b platelet antigens. All phenotyping results were 100% concordant with the HPA-1 or HPA-5 genotype. The test can be performed from only 10 µl of fresh or frozen blood samples within less than 15 min time-to-result.

2.
Transfusion ; 55(11): 2742-51, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26173471

RESUMO

BACKGROUND: Fetomaternal alloimmune thrombocytopenia (FMAIT) is caused by human platelet (PLT) antigen (HPA) incompatibility. Beads coupled with recombinant ß3 integrins, displaying the biallelic HPA-1 epitopes (rHPA-1), have been shown to detect HPA-1a alloantibodies implicated in FMAIT. This report describes a multicenter validation of the beads using the results of well-characterized samples to define the optimum parameters for analysis of a large cohort of 498 clinical samples. STUDY DESIGN AND METHODS: Fifty-one blinded quality assurance (QA) samples were tested by six laboratories to standardize the rHPA-1 bead assay and to develop an algorithm for sample classification. Five laboratories retrieved samples from 498 independent FMAIT cases, previously tested by the monoclonal antibody-specific immobilization of PLT antigens (MAIPA) assay, from their local archives for testing with the rHPA-1 beads. The results were evaluated using a mathematical algorithm developed to classify the samples. RESULTS: The QA samples gave a mean concordance of 94% between the bead and MAIPA assays, while 97% concordance was observed with the FMAIT samples. Of the 15 discrepant samples, seven were positive by the beads but negative by MAIPA, while the contrary was observed for eight samples. Overall, the bead assay achieved 98% sensitivity for HPA-1a antibody detection in FMAIT and 98.7% specificity compared to the local MAIPA. CONCLUSION: The rHPA-1 bead assay is a rapid 3-hour assay for the sensitive detection of HPA-1 antibodies. Its ease of use would enable prompt detection of maternal HPA-1a antibodies in suspected FMAIT cases, which is important supportive evidence for treatment by transfusion with HPA-1b1b PLTs.


Assuntos
Antígenos de Plaquetas Humanas/imunologia , Isoanticorpos/imunologia , Trombocitopenia Neonatal Aloimune/imunologia , Algoritmos , Alelos , Feminino , Humanos , Integrina beta3/genética , Masculino , Polimorfismo de Nucleotídeo Único/genética
3.
Platelets ; 26(5): 421-4, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25101933

RESUMO

Fetal/neonatal allo-immune thrombocytopenia is the most frequent and the most dangerous clinical condition involving anti-human platelet antigens (HPA)-1a allo-antibodies. Anti-HPA-1a allo-immunization requires rapid and accurate diagnosis to determine appropriate treatment. The Capture-P Ready-Screen assay (C-PRS) is a new qualitative immunoassay to detect IgG anti-human leukocyte antigen (HLA) and anti-HPA allo-antibodies. The aim of this study is to assess the identification of anti-HPA-1a allo-antibodies using the C-PRS assay, associated with HLA class I stripping reagents, on the automated benchtop analyzer Galileo Echo. Forty-nine sera were analyzed: without anti-HLA class I or anti-HPA allo-antibodies, with anti-HLA class I allo-antibodies, with anti-HPA-1a allo-antibodies, among which with anti-HLA class I allo-antibodies. None of the samples without allo-antibodies were reactive. Only anti-HLA antibodies, detected by cytotoxicity-dependent complement and not by Luminex, remained positive before and after stripping reagents. Of the 13 samples, anti-HPA-1a allo-antibodies that were correctly identified before and after incubation with HLA assassin reagent were 70% and 85%, respectively. Anti-glycoprotein auto-antibodies and anti-HLA allo-antibodies do not interfere with the detection of anti-HPA-1a antibodies. This preliminary study indicates that further improvement of the test will be helpful in developing a clinically useful assay in the future.


Assuntos
Antígenos de Plaquetas Humanas/imunologia , Plaquetas/imunologia , Imunoensaio/instrumentação , Imunoensaio/métodos , Imunoglobulina G/imunologia , Isoanticorpos/imunologia , Autoanticorpos/sangue , Autoanticorpos/imunologia , Proteína C-Reativa , Antígenos HLA/imunologia , Humanos , Imunoglobulina G/sangue , Integrina beta3 , Isoanticorpos/sangue , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Haematologica ; 97(5): 696-704, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22133781

RESUMO

BACKGROUND: Neonatal alloimmune thrombocytopenia is mostly due to the presence of maternal antibodies against the fetal platelet antigen HPA-1a on the platelet integrin GPIIb-IIIa. Accurate detection of anti-HPA-1a antibodies in the mother is, therefore, critical. Current diagnostic assays rely on the availability of pools of human platelets that vary according to donors and blood centers. There is still no satisfactory standardization of these assays. DESIGN AND METHODS: Peptide aptamer was used to detect and identify HPA-1a-specific antibodies in human serum that do not require human platelets. A peptide aptamer library was screened using an anti-HPA-1a human monoclonal antibody as a bait to isolate an aptamer that mimics the human platelet antigen HPA-1a. RESULTS: This is the first report in platelet immunology of the use of a peptide aptamer for diagnostic purposes. This assay gives better results than the MAIPA currently in use, detecting around 90% of the expected alloantibodies. CONCLUSIONS: This assay could help define a standard for the quantitation of anti-HPA antibodies. This report also demonstrates that peptide aptamers can potentially detect a variety of biomarkers in body fluids; this is of particular interest for diagnostic purposes.


Assuntos
Anticorpos Anti-Idiotípicos/sangue , Antígenos de Plaquetas Humanas/imunologia , Aptâmeros de Nucleotídeos , Plaquetas/imunologia , Isoanticorpos/sangue , Fragmentos de Peptídeos , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/imunologia , Trombocitopenia Neonatal Aloimune/diagnóstico , Sequência de Aminoácidos , Anticorpos Anti-Idiotípicos/imunologia , Anticorpos Monoclonais/imunologia , Complexo Antígeno-Anticorpo , Western Blotting , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Imunoensaio , Imunoprecipitação , Recém-Nascido , Integrina beta3 , Isoanticorpos/imunologia , Dados de Sequência Molecular , Trombocitopenia Neonatal Aloimune/sangue , Trombocitopenia Neonatal Aloimune/imunologia
5.
Biosens Bioelectron ; 26(4): 1631-7, 2010 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-20851593

RESUMO

An evanescent wave fluorescence biosensor was combined with a DNA bio-barcode assay to resolve problems met in detection of poor biologic samples. Human platelet antigen (HPA) genotyping was used as a demonstrator. Our bio-barcode assay was based on magnetic carboxylatex particles and non-magnetic carboxylatex particles, both functionalized with oligonucleotides. It was assessed for detecting 84mer synthetic oligonucleotides as targets. The assay allows to specifically detect single nucleotide polymorphism with a detection limit of 2 pM of target nucleic acids. The fluorescence detection is achieved in 150 s.


Assuntos
Antígenos de Plaquetas Humanas/genética , Técnicas Biossensoriais/métodos , Plaquetas/imunologia , Código de Barras de DNA Taxonômico/métodos , Técnicas Biossensoriais/instrumentação , Código de Barras de DNA Taxonômico/instrumentação , Fluorescência , Genótipo , Humanos , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Sondas de Oligonucleotídeos , Polimorfismo de Nucleotídeo Único
6.
Anal Biochem ; 400(1): 10-8, 2010 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-20079705

RESUMO

Protein microarray technology provides a useful approach for the simultaneous serodetection of various antibodies in low sample volumes. To implement functional protein microarrays, appropriate surface chemistry must be designed so that both the protein structure and the biological activity can be retained. In the current study, two surface chemistries for protein microarrays and immunofluorescent assays were developed. Glass slides were functionalized with N-hydroxysuccinimide (NHS) ester via a monofunctional silane or maleic anhydride-alt-methyl vinyl ether (MAMVE) copolymer to allow covalent grafting of histone proteins. Analytical performance of these microarrays was then evaluated for the detection of anti-histone autoantibodies present in the sera of patients suffering from a systemic autoimmune disease, namely systemic lupus erythematosus (SLE), and the results were compared with those of the classical enzyme-linked immunosorbent assay (ELISA) and Western blot. The detection limit of our MAMVE copolymer microarrays was 50-fold lower than that of the classical ELISA. Furthermore, 100-fold less volume of biological samples was required with these miniaturized immunoassays.


Assuntos
Imunoensaio/métodos , Análise Serial de Proteínas/métodos , Autoanticorpos/sangue , Western Blotting/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Histonas/química , Histonas/imunologia , Histonas/metabolismo , Humanos , Proteínas Imobilizadas/química , Proteínas Imobilizadas/imunologia , Proteínas Imobilizadas/metabolismo , Lúpus Eritematoso Sistêmico/metabolismo , Miniaturização , Copolímero de Pirano/química , Silanos/química
7.
Artigo em Inglês | MEDLINE | ID: mdl-18002437

RESUMO

Protein microarray technology has shown great advancements in the field of biomedical research and diagnosis, it allows to study and understand protein activities and protein - ligand interactions (e.g. detection of antigen-autoantibody interaction in autoimmune diseases. Autoantibodies are frequently targeted against antigens of the cell nucleus (double and single stranded DNA, histones, and nuclear antigens). The biological activities of proteins (e.g. enzymes, antibodies...) are controlled by peptides sequences of the active site. Consequently, we were interested in the investigation of peptide microarrays in order to further implement in situ peptide synthesis, in particular, deprotection reaction on glass supported peptides. In this work, a protected and biotinylated synthetic peptide was covalently immobilized onto amino functionalized glass surface by activation of its the C-terminus; this allows to orientate the peptide onto the surface. The peptide contains a fragment of the C-terminal end of the human histone H3 protein. The immobilized peptide was then deprotected by using concentrated trifluoroacetic acid solution. After the deprotection, surface stability and peptide grafting density were evaluated by indirect labelling of the immobilized peptide using Cy3 streptavidin conjugates. We also studied biological interaction of IgG polyclonal anti-histone H3 antibody with the immobilized peptide epitope to insure the efficiency of the acid deprotection. The specificity of the antibody interaction with the protected versus non protected peptides. This approach may be applied to in situ synthetic and prototected peptides, in order to elaborate a micro-immunoassay prototype for measurement of peptide-protein interactions on high density microarrays, and detection of antibodies in biological fluids such as serum.


Assuntos
Vidro , Histonas/química , Imunoglobulina G/química , Biblioteca de Peptídeos , Peptídeos/química , Análise Serial de Proteínas/instrumentação , Proteínas/química , Sequência de Aminoácidos , Anticorpos/química , Biotinilação , Ensaio de Imunoadsorção Enzimática/métodos , Desenho de Equipamento , Humanos , Ligantes , Dados de Sequência Molecular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...